BXKFG - RP 1118 HARDENER

Product Identification

Product ID:RP 1118 HARDENER
MSDS Date:01/30/1991
FSC:8040
NIIN:00F004826
MSDS Number: BXKFG

Responsible Party
CIBA-GEIGY CORP FORMULATED SYSTEMS GROUP
4917 DAWN AVE
EAST LANSING, MI 48823-5605
US

Emergency Phone: 517-351-5900/800-888-8372

Info Phone: 517-351-5900/800-888-8372

Cage: 02684

Contractor
CIBA SPECIALTY CHEMICALS CORPORATION
EAST LANSING, MI 48823-5691 US

Telephone: 517-351-5900

Cage: 02684

Ingredients

1-METHYL IMIDAZOLE

CAS: 616-47-7

RTECS: NI7000000


M-XYLENE DIAMINE

CAS: 1477-55-0

RTECS: PF8970000

OSHA PEL 0.1 MG/M3 (SKIN)

ACGIH TLV: C 0.1 MG/CUM (SKIN)


1,3 BENZENEDIMETHANAMINE,POLYMER W/2,2'-(1-METHYL

CAS: 68738-77-2


BISPHENOL A, BISPHENOL

CAS: 80-05-7

RTECS: SL6300000


DIETHYLENETRIAMINE, ETHYLENEDIAMINE, N-(2-AMINOETHYL)

CAS: 111-40-0

RTECS: IE1225000

OSHA PEL 4 MG/M3 AIR TWA

ACGIH TLV: 4 MG/M3 AIR (SKIN)


TRIETHYLENETETRAMINE, EPOXY HARDNER

CAS: 112-24-3

RTECS: YE6650000

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYES: CORROSIVE, CAUSES BURNS.
SENSITIZATION POSSIBLE IN SUSCEPTIBLE INDIVIDUALS. CAUSES ALLERGIC
SKIN & RESPIRATORY REACTIONS. HARMFUL IF ABSORBED THROUGH SKIN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:BURNS, NAUSEA, VOMITING.
Medical Cond Aggravated by Exposure:SKIN & EYE CONDITIONS

First Aid

First Aid:EYES: IMMEDIATELY FLUSH W/WATER FOR 15 MINS. SKIN: WASH
W/SOAP & WATER. INGESTION: IF CONSCIOUS, GIVE PLENTY OF WATER TO
DRINK. DON'T INDUCE VOMITING. INHALATION: REMOVE TO FRESH AIR. GIVE
OXYGEN/CPR IF NEEDED. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>260F
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER.
Fire Fighting Procedures:USE SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:DECOMPOSITION & COMBUSTION PRODUCTS MAY
BE TOXIC.

Accidental Release

Spill Release Procedures:REMOVE BY ABSORBING IN ABSORBENT MATERIAL.
AVOID CONTACT.

Handling

Handling and Storage Precautions:CORROSIVE. KEEP CONTAINER CLOSED. USE
W/ADEQUATE VENTILATION. NUISANCE DUST MAY BE GENERATED WHEN
SANDING/SAWING CURED MATERIAL.
Other Precautions:DON'T GET INTO EYES, ON SKIN/CLOTHING. AVOID
BREATHING VAPORS/MIST.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED ORGANIC VAPOR CARTRIDGE
RESPIRATOR WHEN VAPOR/MIST EXPOSURE IS LIKELY.
Ventilation:GENERAL MECHANICAL & LOCAL EXHAUST IAW/ACGIH
RECOMMENDATIONS.
Protective Gloves:IMPERMEABLE
Eye Protection:FULL FACE SHIELD
Other Protective Equipment:REQUIRED.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health

Chemical Properties

Spec Gravity:1.03-1.05
Solubility in Water:MODERATE
Percent Volatiles by Volume:<1

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, ACIDS, METAL-ORGANIC COMPOUNDS
Stability Condition to Avoid:EXCESSIVE HEAT
Hazardous Decomposition Products:CO, CO2

Disposal

Waste Disposal Methods:CONSULT QUALIFIED LOCAL/CORPORATE PERSONNEL FOR
METHOD THAT WILL COMPLY W/STATE, LOCAL & FEDERAL HEALTH &
ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.